Enabling and disabling SOC

The FortiAnalyzer SOC module can be disabled for performance tuning through the CLI. When disabled, the GUI will hide the SOC modules as well as the FortiView and Monitors panes, and stop background processing for this feature.

To disable SOC in the CLI:

config system global set disable-module fortiview-noc

end

To enable SOC in the CLI:

config system global unset disable-module end

Disabling the SOC module will cause the FortiAnalyzer to return the following error message when the FortiGate attempts to retrieve FortiAnalyzer data: Server Error: FortiView\/NOC function is disabled on FortiAnalyzer.

The FortiGate GUI displays the message: Failed to retrieve FortiView data.

 

This entry was posted in Administration Guides, FortiAnalyzer on by .

About Mike

Michael Pruett, CISSP has a wide range of cyber-security and network engineering expertise. The plethora of vendors that resell hardware but have zero engineering knowledge resulting in the wrong hardware or configuration being deployed is a major pet peeve of Michael's. This site was started in an effort to spread information while providing the option of quality consulting services at a much lower price than Fortinet Professional Services. Owns PacketLlama.Com (Fortinet Hardware Sales) and Office Of The CISO, LLC (Cybersecurity consulting firm).