CLI changes for FortiLink mode

CLI changes for FortiLink mode (447349, 473773)

There are changes to the execute switch-controller get-physical-connection, execute switch-controller get-conn-status, and diagnose switch-controller dump networkupgrade status CLI commands.

  • The execute switch-controller get-physical-connection CLI command has new parameters:

Use the execute switch-controller get-physical-connection standard command to get the FortiSwitch stack connectivity graph in the standard output format.

Use the execute switch-controller get-physical-connection dot command to get the

FortiSwitch stack connectivity graph in a .dot (Graphviz) output format.

  • The execute switch-controller get-conn-status CLI command output now includes virtual

FortiSwitch units. Virtual FortiSwitch units are indicated by an asterisk (*) after the switch identifier. For example:

execute switch-controller get-conn-status

STACK-NAME: FortiSwitch-Stack-port2      
SWITCH-ID            VERSION STATUS ADDRESS JOIN-TIME NAME
S108DV2EJZDAC42F     v3.6.0 Authorized/Up 169.254.2.4 Thu Feb 8 17:07:35 2018
S108DV4FQON40Q07     v3.6.0 Authorized/Up 169.254.2.5 Thu Feb 8 17:08:37 2018
S108DVBWVLH4QGEB     v3.6.0 Authorized/Up 169.254.2.6 Thu Feb 8 17:09:13 2018
S108DVCY19SA0CD8     v3.6.0 Authorized/Up 169.254.2.2 Thu Feb 8 17:04:41 2018
S108DVD98KMQGC44* v3.6.0 Authorized/Up 169.254.2.7 Thu Feb 8 17:10:50 2018
S108DVGGBJLQQO48* v3.6.0 Authorized/Up 169.254.2.3 Thu Feb 8 17:06:57 2018
S108DVKM5T2QEA92     v3.6.0 Authorized/Up 169.254.2.8 Thu Feb 8 17:11:00 2018
S108DVZX3VTAOO45     v3.6.0 Authorized/Up 169.254.2.9 Thu Feb 8 17:11:00 2018
Managed-Switches: 8 UP: 8 DOWN: 0      
  • The diagnose switch-controller dump network-upgrade status CLI command output now

includes the location of the image that is loaded when the FortiSwitch unit is restarted. If the Next boot column is blank, the FortiSwitch unit uses the same location each it is restarted. The status column shows the percentage downloaded, the percentage erased in flash memory, and the percentage written to flash memory.

For example:

diagnose switch-controller dump network-upgrade status

Running                                       Status       Next boot

__________________ ________________________________________ _________ ___________________________ VDOM : root

S108DVCY19SA0CD8 S108DV-v3.6.0-build4277,171207 (Interim) (0/0/0) S108DV-v3.7.0build4277,171207 (Interim)

S108DV2EJZDAC42F S108DV-v3.6.0-build4277,171207 (Interim) (0/0/0)

This entry was posted in Administration Guides, FortiOS 6, FortiSwitch on by .

About Mike

Michael Pruett, CISSP has a wide range of cyber-security and network engineering expertise. The plethora of vendors that resell hardware but have zero engineering knowledge resulting in the wrong hardware or configuration being deployed is a major pet peeve of Michael's. This site was started in an effort to spread information while providing the option of quality consulting services at a much lower price than Fortinet Professional Services. Owns PacketLlama.Com (Fortinet Hardware Sales) and Office Of The CISO, LLC (Cybersecurity consulting firm).