FortiSIEM Hardware Monitoring Events

Hardware Monitoring Events

AccelOps generates the following events related to hardware monitoring

Overall Hardware Status

Individual Hardware Component Status

Temperature Measurement

Humidity Measurement

Dew point Measurement

Air flow Measurement

Audio Measurement

Ampere Measurement

Dry Contact Measurement

Camera Motion Measurement

Power Supply Measurement

Chassis Component Measurement

Overall Hardware Status Event

This event is generated by AccelOps as a overall hardware status. Sometimes this overall status is provided the device. In other times, AccelOps derives the overall health from that of the individual hardware components.

Event Type: PH_DEV_MON_HW_STAT

Description: Event containing overall hardware status as detected by AccelOps

Cisco IOS (SNMP),Cisco Nx-OS (SNMP), Juniper JunOS (SNMP), Juniper SRX JunOS (SNMP), Alcatel TiMOS (SNMP), Alcatel

AOS (SNMP),Avaya/Nortel ERS (SNMP), Huawei VRP (SNMP), H3C Comware,

EMC Clariion (NavisecCli), NetApp DataONTAP Filer (SNMP), Dell EqualLogic (SNMP)

F5 Big-IPOS (SNMP), Riverbed Steelhead (SNMP), InfoBlox NiOS (SNMP)

Virtual Machines on VMWare ESX (VMSDK), Windows/Linux Servers on Dell hardware with OpenManage installed (SNMP),

Windows/Linux Servers on HP hardware with HP Insight Manager installed (SNMP),

APC NetBotz (SNMP)

Cisco UPS (UCS API)

HP BladeSystem (SNMP)

Key Attributes: Varies depending on the source. The global set of attributes is shown below

Name Id Type Description
Event Type eventType string Event type set to PH_DEV_MON_HW_STAT
Event Severity eventSeverity uint16 0 if the event attribute hwStatusCode is 0 (Normal), 5  if hwStatusCode is 1 (Warning) and 10  if hwStatusCode is 2 (Critical)
Event Severity

Category

eventSeverityCat string Set to Low. In general, takes the values Low, Medium and High. Event Severities 0-4 are mapped to

Low, 5-8 are mapped to Medium and 9-10 are mapped to High

Event Receive

Time

phRecvTime Date Time at which AccelOps generated this event
Reporting IP reptDevIpAddr Date IP address of device reporting this event. In this case set to the device reporting the utilization (same as Host name attribute)
Relaying IP relayDevIpAddr Date IP address of device relaying this event from the source to AccelOps. In general it could be a syslog-ng IP address but in this, since AccelOps talks to the device directly, Relaying IP is set to AccelOps IP Address.
Raw Event Log rawEventMsg string Raw event containing all attributes in comma separated “[Attribute] = value” format.
Host name hostName string Host name (as in AccelOps CMDB) of the device whose overall hardware health is being reported
Host IP Address hostIpAddr IP Access IP (as in AccelOps CMDB) of the device whose overall hardware health is being reported
Hardware Status hwStatusCode uint16 Overall hardware status: 0 for Normal, 1 for Warning and 2 for Critical
Hardware Power

Supply Status

hwPowerSupplyStatus uint16 Overall hardware status: 0 for Normal, 1 for Warning and 2 for Critical
Hardware

Battery Status

hwBatteryStatus uint16 Battery status: 0 for Normal, 1 for Warning and 2 for Critical
Hardware Disk

Status

hwDiskStatus uint16 Disk status: 0 for Normal, 1 for Warning and 2 for Critical
Hardware RAID

Status

hwRaidStatus uint16 Hardware RAID status: 0 for Normal, 1 for Warning and 2 for Critical
Hot Spare Disk

Count

hwHotSpareDiskCount uint16 Number of hot spare disks
Hardware

Memory Status

hwMemoryStatus uint16 Memory status: 0 for Normal, 1 for Warning and 2 for Critical
Hardware Status hwPowerSupplyStatus uint16 Power supply status: 0 for Normal, 1 for Warning and 2 for Critical
Failed Power

Supply Count

hwFailedPowerSupplyCount uint16 Number of failed power supplies
Hardware Temp

Sensor Status

hwTempSensorStatus uint16 Temperature sensor status: 0 for Normal, 1 for Warning and 2 for Critical
Hardware Status hwFanStatus uint16 Fan status: 0 for Normal, 1 for Warning and 2 for Critical
Failed Fan

Count

hwFailedFanCount uint16 Failed fan count
Hardware Amp

Status

hwAmpStatus uint16 Current (Amp) status: 0 for Normal, 1 for Warning and 2 for Critical
Hardware

Voltage Status

hwVoltageStatus uint16 Voltage status: 0 for Normal, 1 for Warning and 2 for Critical
Storage LCC

Status

hwLCCStatus uint16 Hardware LCC status: 0 for Normal, 1 for Warning and 2 for Critical
Storage Link

Status

hwLinkStatus uint16 Hardware link status: 0 for Normal, 1 for Warning and 2 for Critical
Storage Port

Status

hwPortStatus uint16 Hardware port status: 0 for Normal, 1 for Warning and 2 for Critical
Relative

Humidity Status

hwRelHumidStatus uint16 Relative humidity status: 0 for Normal, 1 for Warning and 2 for Critical
Dew Point

Status

hwDewPtStatus uint16 Dew Point status: 0 for Normal, 1 for Warning and 2 for Critical
Audio Status hwAudioStatus uint16 Audio status: 0 for Normal, 1 for Warning and 2 for Critical
Air Flow Status hwAirFlowStatus uint16 AIr flow status: 0 for Normal, 1 for Warning and 2 for Critical
Generic

Numeric Sensor

Status

hwGenNumericSensorStatus uint16 Generic Numeric sensor status: 0 for Normal, 1 for Warning and 2 for Critical
Dry Contact

Status

hwDryContactStatus uint16 Dry Contact status: 0 for Normal, 1 for Warning and 2 for Critical
Door Switch

Status

hwDoorSwitchStatus uint16 Door switch status: 0 for Normal, 1 for Warning and 2 for Critical
Camera Motion

Status

hwCameraMotionStatus uint16 Camera motion status: 0 for Normal, 1 for Warning and 2 for Critical
Generic State

Sensor Status

hwGenStateSensorStatus uint16 Generic state sensor status: 0 for Normal, 1 for Warning and 2 for Critical

The following table indicates sources of various hardware status events.

Device

Type

(Method)

Overall Temp Power

Supply

Fan Chassis Memory Disk RAID Battery Amp Voltage LCC Storage

Link

Storage

Port

Humidity Air flow Dew

Point

Audio Gen

Numeric

Sensor

Dry

Contact

Door

Swit

Cisco IOS

(SNMP)

x x x x
Cisco Nx-OS

(SNMP)

x x
Juniper

JunOS

(SNMP),

x x x x
Juniper SRX

JunOS

(SNMP)

x x x x
Alcatel TiMOS

(SNMP)

x x x x
Alcatel AOS

(SNMP)

x x
Huawei VRP

(SNMP)

H3C

Comware

(SNMP)

x x
EMC Clariion

(NavisecCli)

x x x x x x x

c

NetApp

DataONTAP

Filer (SNMP)

x x x x x x x x x
Dell

EqualLogic

(SNMP)

x x x x x x
F5 Big-IPOS

(SNMP)

x x x
Riverbed

Steelhead

(SNMP)

x
InfoBlox NiOS

(SNMP)

x x x x x x

 

VMs on ESX

(VMSDK)

Dell Servers x x x x x x x x x
HP Servers x x x x x x x x x
APC NetBotz x x x x x x x x x
Cisco UCS
HP

BladeSystem

x x x
This entry was posted in Administration Guides, FortiSIEM on by .

About Mike

Michael Pruett, CISSP has a wide range of cyber-security and network engineering expertise. The plethora of vendors that resell hardware but have zero engineering knowledge resulting in the wrong hardware or configuration being deployed is a major pet peeve of Michael's. This site was started in an effort to spread information while providing the option of quality consulting services at a much lower price than Fortinet Professional Services. Owns PacketLlama.Com (Fortinet Hardware Sales) and Office Of The CISO, LLC (Cybersecurity consulting firm).